    A procedure for sizing pump-pipe systems with regard to minimising life cycle costs manageable on excel spreadsheets

    Thumbnail
    View/Open
    Main article (808.2Kb)
    Date
    2016-02
    Author
    Hove, T
    Mushiri, T
    Type
    Article
    Metadata
    Show full item record

    Abstract
    Pump-pipeline systems are a common feature of every industry and account for about 20% of the world’s electrical energy demand. Pump and pipe selection should happen simultaneously in pump-pipe system design rather than first sizing the pipe and then finding the pump to go with the pipe. Further, proper selection of systems should go beyond just considering only the initial cost but the total cost of ownership- the life cycle cost (LCC). In this paper a spreadsheet tool is developed for pump-pipe system technical analysis with the output design parameters facilitating LCC analysis. The program can calculate the operating point of any size of pump, at any given speed and with any pipe size and by use of appropriate cost models determine the unit cost of pumping for each system. Dimensionless pump characteristic curves that are generic for all radial flow pumps are modelled by multi-polynomial equations. Dimensional similitude can then be used to determine the actual characteristic curves for any pump of given impeller diameter and rotational speed. The system resistance curve is calculated from well-known hydraulic formulae and represented by a quadratic equation. The operating point of the pump-pipe system is obtained from a simultaneous solution of the quadratic equations representing the pump and the pipe resistance curves. Best practice technical constraints, like maximum deviation from best-efficiency point (BEP), allowable net positive suction head and maximum allowable operating hours, can be set by the designer. Operating the pump-pipe system near best efficiency point is desirable since it reduces both energy and pump maintenance costs. A pump-pipe system is selected only if it falls within designer-specified best practice constraints. The life cycle cost of each system that passes the first test is then calculated using discounting techniques and the pump-pipe system with the least LCC is adopted.
    URI
    http://hdl.handle.net/10646/2828
    Additional Citation Information
    Hove, T. & Mushiri, T. (2016). A procedure for sizing pump-pipe systems with regard to minimising life cycle costs manageable on excel spreadsheets. ZIE Journal of Science, Engineering and Technology (JSET), 3(1), 23-27.
    Sponsor
    Zimbabwe Institution of Engineers
    Publisher
    Zimbabwe Institution of Engineers
    Subject
    Dimensional similitude
    Pump-pipe Life Cycle Cost
    Best Efficiency Point
    Best practice
    Collections
    • Mechanical Engineering Staff Publications [13]

    University of Zimbabwe: Educating To Change Lives!
    DSpace software copyright © 2002-2020  DuraSpace | Contact Us | Send Feedback
     

     

    Browse

    All of UZ eScholarCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage StatisticsView Google Analytics Statistics

    University of Zimbabwe: Educating To Change Lives!
    DSpace software copyright © 2002-2020  DuraSpace | Contact Us | Send Feedback