University of Zimbabwe Institutional Repository

POSSIBLE SIMPLIFIED RATE MODELS FOR THE STUDY OF THE EMISSION SIGNAL ENHANCEMENT DUE TO EASILY IONIZABLE ELEMENTS DURING FLAME ATOMIC EMISSION (FAES) AND INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMMETRY (ICP-OES)

Show simple item record

dc.contributor.author Mahamadi, Courtie
dc.date.accessioned 2012-08-02T10:42:51Z
dc.date.available 2012-08-02T10:42:51Z
dc.date.issued 2012-08-02
dc.identifier.uri http://hdl.handle.net/10646/816
dc.description.abstract The effects of excess Na and K on K and Mg atom line emission during air-acetylene flame atomic spectrometry (FAES), and of excess Li and K on Ca, Mg and Sr atom and ion lines in the inductively coupled plasma (ICP), were studied using emission signal ratios, E’/E as probes, where E’ and E are the emission readings in the presence and absence of the interferent respectively. The E’/E plots as a function of analyte concentration in the test solution for the ICP experiments were similar to those obtained for the flame experiments in the analytical range of 0-10 mg/L. Two possible rate models: a simplified rate model based on analyte excitation via charge transfer between analyte ions and activated interferent atoms, and a collisional rate model based on ambipolar diffusion have been proposed to account for the emission signal enhancement observed at low analyte concentrations (<1 mg/L) for both ICP-OES and FAES. Data are presented comparing the experimental E’ calibration curves and theoretical E’ calibration curves computed using the simplified rate models. The collisional charge transfer model showed good agreement for analyte concentration range spanned. Empirical values of collisional de-excitation rate constants (kCD) values were obtained using the ambipolar diffusion model and these values were found to vary inversely with analyte ion concentration. The results also showed that kCD values were independent of interferent concentration, for the situation of high interferent/low analyte concentration. en_ZW
dc.language.iso en_ZW en_ZW
dc.subject ionization en_ZW
dc.subject spectrometry en_ZW
dc.subject plasma atomic en_ZW
dc.title POSSIBLE SIMPLIFIED RATE MODELS FOR THE STUDY OF THE EMISSION SIGNAL ENHANCEMENT DUE TO EASILY IONIZABLE ELEMENTS DURING FLAME ATOMIC EMISSION (FAES) AND INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMMETRY (ICP-OES) en_ZW
dc.contributor.registrationnumber R931603W en_ZW
thesis.degree.advisor Kugara, J. (Dr.)
thesis.degree.advisor Zaranyika, Mark. F. (Prof.)
thesis.degree.country Zimbabwe en_ZW
thesis.degree.discipline Chemistry en_ZW
thesis.degree.faculty Faculty of Science en_ZW
thesis.degree.grantor University of Zimbabwe en_ZW
thesis.degree.grantoremail specialcol@uzlib.uz.ac.zw
thesis.degree.level DPhil en_ZW
thesis.degree.name Doctor of Philosophy en_ZW
thesis.degree.thesistype Dissertation en_ZW
dc.date.defense 2007-07-26


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search UZeScholar


Browse

My Account

xmlui.statisticsGoogleAnalytics.Navigation.title